Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Rev. adm. pública (Online) ; 55(3): 716-735, maio-jun. 2021. graf
Article in Portuguese | LILACS | ID: biblio-1288130

ABSTRACT

Resumo Discussão acerca da crise fiscal dos estados e do Regime de Recuperação Fiscal (RRF), promulgado no ano de 2017, cujas medidas de ajuste são apontadas como fundamentais para o equilíbrio das contas públicas estaduais e que representam, no entanto, sob a perspectiva federativa, um enfraquecimento dos estados brasileiros, já que tais medidas afetam a autonomia político-administrativa destes entes subnacionais. O estado do Rio de Janeiro foi objeto desta pesquisa entre os anos de 2008 e 2019, pois foi o único a aderir ao RRF desde sua promulgação. O estudo indica que as medidas de austeridade adotadas pelo estado do Rio de Janeiro não foram suficientes para garantir a estabilidade financeira e o reequilíbrio das contas públicas. Dentre os resultados, destacam-se a manutenção da insolvência financeira, bem como o crescimento do endividamento do período, sendo o único resultado positivo, no âmbito dos termos do RRF, a redução dos gastos com pessoal. Por fim, observa-se que, até o penúltimo quadrimestre de 2019, o estado do Rio de Janeiro não cumpriu integralmente o acordo firmado com a União.


Resumen Este artículo tiene como objetivo discutir la crisis fiscal de los estados brasileños y el Régimen de Recuperación Fiscal (RRF) promulgado en 2017, cuyas medidas de ajuste se consideran fundamentales para el saldo de las cuentas públicas estatales, pero también representan, bajo la perspectiva federativa, un debilitamiento de los estados brasileños, ya que tales medidas afectan la autonomía política y administrativa de estas entidades subnacionales. El estado de Río de Janeiro fue objeto de esta investigación entre los años 2008 y 2019 porque fue el único estado que se adhirió al RRF desde su promulgación. El estudio indica que las medidas de austeridad adoptadas por el estado de Río de Janeiro no fueron suficientes para garantizar la estabilidad financiera y el reequilibrio de las cuentas públicas. Entre los resultados, destacamos el mantenimiento de la insolvencia financiera, así como el crecimiento del endeudamiento en el período y el único resultado positivo dentro de los términos del RRF es la reducción de los gastos de personal. Finalmente, se observa que hasta el penúltimo cuatrimestre de 2019, el estado de Río de Janeiro no cumplió plenamente el acuerdo firmado con el Gobierno Federal.


Abstract This article aims to discuss the fiscal crisis of the Brazilian states and the Fiscal Recovery Regime (FRR) enacted in 2017, whose adjustment measures are considered fundamental for the balance of state public accounts. Under the federative perspective, these adjustments represent a weakening of the states since such measures affect their political and administrative autonomy. The state of Rio de Janeiro was chosen as the subject of this research because it was the only state to join the FRR since its enactment, and the study used data from the years 2008 to 2019. The findings suggest that the austerity measures adopted by the state of Rio de Janeiro were not enough to guarantee financial stability and the rebalancing of public accounts. Among the results, we highlight that the state remained financially insolvent and the indebtedness for the period grew. The only positive result within the terms of the FRR was the reduction in the state's personnel expenses. Finally, it is noted that until the penultimate quarter of 2019, the state of Rio de Janeiro did not comply with the terms of the agreement signed with the federal government.


Subject(s)
Politics , State , Federalism , Federal Government , Budgets
2.
Rev. bras. ginecol. obstet ; 35(2): 49-54, fev. 2013. graf, tab
Article in Portuguese | LILACS | ID: lil-666187

ABSTRACT

OBJETIVO: Avaliar o desempenho de uma curva de altura uterina (AU) quanto à capacidade de rastrear desvios do volume de líquido amniótico, utilizando uma curva brasileira de índice de líquido amniótico (ILA) como padrão-ouro. MÉTODOS: O presente estudo representa um corte transversal no qual foram incluídas 753 gestantes em acompanhamento pré-natal na rede pública de João Pessoa (PB) no período de março a outubro de 2006 e que tiveram um exame de ultrassonografia (US) de rotina agendado para depois da 26ª semana de idade gestacional. Foram excluídos os casos com diagnóstico de gestação gemelar, óbito fetal intrauterino e malformações fetais maiores. Além de informações sociodemográficas, foram coletados também os valores da AU medida de forma padronizada, os valores do peso fetal estimado, do ILA e a idade gestacional pelo exame de US. A capacidade da curva de AU em predizer os desvios do volume de líquido amniótico foi avaliada tendo uma curva brasileira de ILA em função da idade gestacional como padrão-ouro. Para isso, foram estimados a sensibilidade, especificidade e valores preditivos positivo e negativo para diferentes pontos de corte. RESULTADOS: A medida da AU identificou 10,5% das mulheres como AU baixa e possivelmente associada ao oligoâmnio, e 25,2% como AU alta e possivelmente associada ao polidrâmnio. Utilizando uma curva brasileira de referência para ILA, a AU foi capaz de predizer pobremente a ocorrência de oligoâmnio (sensibilidade variando entre 37 a 28%) e de forma razoável a ocorrência de polidrâmnio (sensibilidade variando entre 88 a 69%). CONCLUSÃO: A medida da altura uterina mostrou um desempenho ruim para predizer oligoâmnio e um desempenho razoável para predizer polidrâmnio. Sua utilização para essa finalidade só se justifica, portanto, em situações nas quais o exame ultrassonográfico não esteja fácil e rotineiramente disponível, a fim de ajudar na priorização dos casos que deveriam ter esse exame realizado.


PURPOSE: To evaluate the performance of a Brazilian reference curve of fundal height (FH) regarding its capacity of screening the deviations of volume of amniotic fluid using a Brazilian reference curve of amniotic fluid index (AFI) as gold standard. METHODS: This was a cross-sectional study evaluating 753 pregnant women receiving prenatal care at the public health services of João Pessoa (PB), from March to October 2006, who had a routine ultrasound exam scheduled for after 26 weeks of gestational age. Cases with diagnoses of twin pregnancy, intrauterine fetal death and major fetal malformations were excluded. Besides socio-demographic information, data regarding fundal height measured in a standard way, estimated fetal weight, AFI and gestational age at the time of the ultrasound exam were also collected. The capacity of the FH curve to predict deviations of the amniotic fluid volume was assessed using the Brazilian curve of AFI according to gestational age as the gold standard. For this purpose, sensitivity, specificity, positive and negative predictive values were estimated for different cut-off points. RESULTS: The measurement of FH identified 10.5% of women as having low FH possibly associated with oligohydramnios and 25.2% as having high FH possibly associated with polyhydramnios. Using a Brazilian reference curve of AFI, the FH was able to poorly predict the occurrence of oligohydramnios (sensitivity ranging from 37 to 28%) and to reasonably predict the occurrence of polyhydramnios (sensitivity ranging from 88 to 69%). CONCLUSIONS: The measurement of fundal height showed a poor performance for predicting oligohydramnios and a reasonable performance for predicting polyhydramnios. Its use for this purpose is then only supported in settings where the ultrasound exam is not easily or routinely available in order to help define priorities for cases that should have this exam performed.


Subject(s)
Adolescent , Adult , Female , Humans , Middle Aged , Pregnancy , Young Adult , Cervical Length Measurement , Oligohydramnios/diagnosis , Polyhydramnios/diagnosis , Brazil , Cross-Sectional Studies , Reference Values
3.
Rev. saúde pública ; 44(6): 1031-1038, dez. 2010. ilus, tab
Article in English | LILACS | ID: lil-565087

ABSTRACT

OBJECTIVE: To validate a new symphysis-fundal curve for screening fetal growth deviations and to compare its performance with the standard curve adopted by the Brazilian Ministry of Health. METHODS: Observational study including a total of 753 low-risk pregnant women with gestational age above 27 weeks between March to October 2006 in the city of João Pessoa, Northeastern Brazil. Symphisys-fundal was measured using a standard technique recommended by the Brazilian Ministry of Health. Estimated fetal weight assessed through ultrasound using the Brazilian fetal weight chart for gestational age was the gold standard. A subsample of 122 women with neonatal weight measurements was taken up to seven days after estimated fetal weight measurements and symphisys-fundal classification was compared with Lubchenco growth reference curve as gold standard. Sensitivity, specificity, positive and negative predictive values were calculated. The McNemar χ2 test was used for comparing sensitivity of both symphisys-fundal curves studied. RESULTS: The sensitivity of the new curve for detecting small for gestational age fetuses was 51.6% while that of the Brazilian Ministry of Health reference curve was significantly lower (12.5%). In the subsample using neonatal weight as gold standard, the sensitivity of the new reference curve was 85.7% while that of the Brazilian Ministry of Health was 42.9% for detecting small for gestational age. CONCLUSIONS: The diagnostic performance of the new curve for detecting small for gestational age fetuses was significantly higher than that of the Brazilian Ministry of Health reference curve.


OBJETIVO: Validar curva de referência de altura uterina por idade gestacional para o rastreamento de desvios do crescimento fetal e comparar sua performance com a curva-padrão adotada pelo Ministério da Saúde do Brasil. MÉTODOS: Estudo observacional que envolveu 753 gestantes de baixo risco de João Pessoa, PB, entre março e outubro de 2006, com idade gestacional acima de 27 semanas. A altura uterina foi medida de acordo com técnica preconizada pelo Ministério da Saúde. O padrão-ouro foi o peso fetal, estimado pelo ultrassom com base na curva de referência brasileira por idade gestacional. Uma subamostra de 122 casos com pesos neonatais obtidos até sete dias depois da estimativa do peso fetal, a classificação da altura uterina foi comparada com a curva de Lubchenco como padrão-ouro. A sensibilidade, a especificidade e os valores preditivos positivo e negativo foram calculados. Para comparar o desempenho da sensibilidade entre ambas as curvas de altura uterina, utilizou-se o teste χ2 de McNemar. RESULTADOS: A sensibilidade da nova curva para a detecção de fetos pequenos para a idade gestacional foi de 51,6 por cento, enquanto a da curva do padrão-ouro foi significativamente menor (12,5 por cento). Na subamostra que teve o peso neonatal como padrão-ouro, a sensibilidade da nova curva de referência foi de 85,7 por cento, enquanto a do Ministério da Saúde exibiu 42,9 por cento de sensibilidade para a detecção de fetos pequenos para a idade gestacional. CONCLUSÕES: A capacidade diagnóstica da nova curva de referência para detectar fetos pequenos para a idade gestacional foi significativamente melhor do que a da curva recomendada pelo Ministério da Saúde.


OBJETIVO: Validar la curva de referencia de altura uterina por edad de gestación para el rastreo de desvíos del crecimiento fetal y comparar su performance con la curva estándar adoptada por el Ministerio de la Salud de Brasil. MÉTODOS: Estudio observacional que envolvió 753 gestantes de bajo riesgo de Joao Pessoa, Noreste de Brasil, entre marzo y octubre de 2006, con edad de gestación por encima de 27 semanas. La altura uterina fue medida de acuerdo con técnica recomendada por el Ministerio de la Salud. El patrón-oro fue el peso fetal, estimado por el ultrasonido con base en la curva de referencia brasilera por edad de gestación. Una sub-muestra de 122 casos con pesos neonatales obtenidos hasta siete días después de la estimación del peso fetal, la clasificación de la altura uterina fue comparada con la curva de Lubchenco como estándar-oro. La sensibilidad, la especificidad y los valores predictivos positivo y negativo fueron calculados. Para comparar el desempeño de la sensibilidad entre ambas curvas de altura uterina, se utilizó la prueba chi-cuadrado de McNemar. RESULTADOS: La sensibilidad de la nueva curva para la detección de fetos pequeños para la edad de gestación fue de 51,6%, mientras que la curva del patrón-oro fue significativamente menor (12,5%). En la sub-muestra que tuvo el peso neonatal como estándar-oro, la sensibilidad de la nueva curva de referencia fue de 87,7%, mientras que la del Ministerio de la Salud exhibió 42,9% de sensibilidad para la detección de fetos pequeños para la edad de gestación. CONCLUSIONES: La capacidad diagnóstica de la nueva curva de referencia para detectar fetos pequeños para la edad de gestación fue significativamente mejor que la curva recomendada por el Ministerio de la Salud.


Subject(s)
Pregnancy , Humans , Embryonic and Fetal Development , Prenatal Diagnosis , Gestational Age , Ultrasonography, Prenatal , Uterus/growth & development
4.
Rev. bras. med. esporte ; 16(4): 264-268, jul.-ago. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-555935

ABSTRACT

O objetivo geral deste estudo foi o de analisar os dados de pico de torque (PT) e índice de fadiga coletados em testes isocinéticos de atacantes (A), meias (M) e defesas (D), a fim de traçar um perfil destes atletas. A amostra foi constituída de 27 jogadores profissionais de futebol com média de idade de 26,55 ± 5,1 anos, divididos nos grupos A (seis), M (sete) e D (14). Os atletas foram submetidos a teste isocinético com cinco repetições máximas de flexão (concêntrica e excêntrica) e extensão (concêntrica) do joelho na velocidade de 60º/s e 30 repetições máximas de flexão e extensão (concêntricas) do joelho na velocidade de 300º/s. A partir dos dados coletados, foi observado que o grupo D apresentou valores significativamente mais elevados de PT concêntrico de flexores do lado dominante (LD) a 60º/s em comparação ao M (p = 0,05). No entanto, para as demais variáveis de PT e índice de fadiga não foram encontradas diferenças entre as posições. Com relação ao déficit bilateral (DB), os atletas apresentaram valores dentro da normalidade. Quanto às razões, foi observado que os jogadores encontravam-se dentro dos valores normativos para razão convencional, porém estavam abaixo dos valores normais para a razão funcional. Conclui-se que, apesar de desempenharem funções diferentes dentro do campo, isso não parece influenciar decisivamente a maioria das características neuromusculares dos membros inferiores nos atletas de futebol avaliados.


The aim of this study was to analyze the data collected from the peak torque (PT) and the fatigue index in isokinetic tests from forwards (F), midfielders (M) and defenders (D) in order to draw a profile of these athletes. Twenty-seven elite male soccer players (mean age 26.55± 5.1 years) were tested, and divided in groups F (6), M (7) and D (14). They were submitted to an isokinetic test with five maximal repetitions of knee flexion (concentric and eccentric) and extension (concentric) at 60º/s and 30 maximal concentric repetitions (flexion and extension) at 300º/s. The collected data evidenced that group D showed significantly higher values of concentric flexors PT at 60 º/s on the dominant side (DS) compared to M (p = 0.05). However, for the other PT variables and fatigue index no differences were found between positions. Concerning bilateral deficit (BD), the athletes presented values within normality. Regarding ratios, it was observed that the players were within the normative values for conventional ratio, but were below the normal values for the functional ratio. We concluded that despite the different positions in the field the players have, this fact does not seem to dramatically influence on the majority of neuromuscular characteristics of lower limbs in the assessed soccer players.


Subject(s)
Humans , Male , Athletes , Physical Exertion/physiology , Knee/physiology , Muscle Fatigue , Soccer , Sports
5.
Rev. bras. ginecol. obstet ; 32(1): 4-10, jan. 2010. tab, ilus
Article in Portuguese | LILACS | ID: lil-539137

ABSTRACT

OBJETIVO: avaliar a correlação entre o peso fetal estimado (PFE) por ultrassonografia e o peso neonatal (PN), bem como a capacidade do PFE predizer as alterações do PN entre gestantes de João Pessoa (PB). MÉTODOS: estudo de validação diagnóstica incluindo 122 gestantes que tiveram o PFE calculado por ultrassonografia até sete dias antes do parto e o PN determinado imediatamente após o nascimento, com balança específica para recém-nascidos. A correlação entre o PFE e o PN foi avaliada pelo coeficiente de correlação de Pearson entre as duas medidas e pela média das diferenças entre elas. O PFE e o PN foram classificados em: pequeno para idade gestacional (PIG), adequado para a idade gestacional (AIG) e grande para a idade gestacional (GIG), de acordo com os percentis 10 e 90 das respectivas curvas de referência. O diagnóstico de desvios do PFE foi validado utilizando a curva de valores de referência de peso neonatal de Alexander como padrão-ouro, estimando-se a sensibilidade, especificidade, valores preditivos positivo e negativo. RESULTADOS: houve uma elevada correlação linear entre o PFE e o PN (R=0,96) e a diferença entre eles variou entre -474 g e +480 g, com média de +3 g. A maioria das máximas variações percentuais da estimativa de peso esteve entre 10 e 15 por cento. O PFE teve sensibilidade de 85,7 por cento e especificidade de 100 por cento para detecção de PIG, e de 100 e 77,2 por cento, respectivamente, para GIG. CONCLUSÕES: o PFE é capaz de predizer adequadamente o PN, e a curva de PFE de referência testada teve bom desempenho no rastreamento dos desvios do crescimento fetal, quando utilizada nessa população.


PURPOSE: to evaluate the correlation between the estimated fetal weight (EFW) by ultrasonography and the neonatal weight (NW), as well as the EFW's capacity to predict changes in NW among pregnant women in João Pessoa, Paraíba, Brazil. METHODS: a diagnostic validation study, including 122 pregnant women who have had the EFW calculated by ultrasonography up to seven days before delivery and the NW established immediately after birth, with a specific newborn's scale. The correlation between EFW and NW measurements was assessed by Pearson's correlation coefficient and by the mean difference between them. EFW and NW were classified as: low for the gestational age (LGA), adequate for the gestational age (AGA) and high for the gestational age (HGA), according to the percentiles 10 and 90 of the respective reference curves. The diagnosis of EFW deviation has been validated using the values of the Alexander's NW reference curve as gold-standard, by estimating the sensitivity, specificity, and positive and negative predictive values. RESULTS: there has been a high linear correlation between the EFW and NW (R=0.96), and the difference between them has varied from -474 g to +480 g, with an average of +3 g. Most of the highest percent weight estimate variations were between 10 and 15 percent. EFW has had 85.7 percent of sensitivity and 100 percent of specificity for the detection of LGA, and 100 and 77.2 percent, respectively, for the detection of HGA. CONCLUSIONS: EFW is able to predict NW adequately, and the reference EFW tested has had a good performance in the screening of fetal growth deviation, in the population studied.


Subject(s)
Adolescent , Adult , Female , Humans , Infant, Newborn , Pregnancy , Young Adult , Birth Weight , Fetal Weight , Ultrasonography, Prenatal , Reference Values , Young Adult
6.
Rev. bras. ciênc. saúde ; 12(3): 289-310, 2008. tab, graf, ilus
Article in English, Portuguese | LILACS | ID: biblio-831283

ABSTRACT

Curvas de referência para valores de parâmetros antropométricosna população são amplamente utilizadas por profissionais desaúde. Técnicas estatísticas de construção de modelosmatemáticos relacionadas com a idade desenvolveram-sebastante nos últimos 10 anos e tem sido uma área de especialinteresse em vários centros de pesquisas no mundo. A evoluçãodo poder de processamento dos computadores pessoais contribuiude maneira significativa para esta mudança nos métodos deanálise de regressão até então utilizados. A publicação do EstudoMulticêntrico de Referência do Crescimento da OMS (2006) criouum novo paradigma para construção de curvas de crescimento, eem consequência, implicou em um amplo questionamento arespeito das curvas anteriormente publicadas e atualmente emuso em várias áreas da saúde. O objetivo deste artigo foi exporde maneira concisa e sem aprofundamento dos aspectosmatemáticos as bases metodológicas da modelagem estatísticautilizando uma nova classe de modelos estatísticos chamadaModelos Aditivos Generalizados para Posição, Escala e Forma(GAMLSS) proposta por RIGBY e STASINOPOULOS (2005).Demonstrou-se a aplicação do método GAMLSS na elaboraçãode um modelo com dados empíricos, a utilização das ferramentasde diagnóstico e de seleção do modelo de melhor ajuste, aconstrução de uma curva de referência e o cálculo facilitado dospercentis e z-escores através de funções específicas. Conclui-seque o método GAMLSS é uma importante ferramenta de modelagemestatística na área da saúde e que em futuras pesquisasprovavelmente será o estado da arte na construção de novascurvas de referência ou na validação de curvas já construídas.


Reference curves for values of anthropometric parameters of apopulation are widely used by healthcare professionals.Statistical techniques for the construction of age-relatedmathematical models have developed a lot in the last 10years and this has been an area of particular interest in severalresearch centers around the world. The evolution of theprocessing power of personal computers has contributedsignificantly to this change in the methods of regression analysisused until then. The WHO publication of the Multicenter GrowthReference Study (MGRS) in 2006 created a new paradigm forthe construction of growth curves, which, consequently, resultedin a broad discussion on the curves previously published andcurrently in use in several healthcare areas. The aim of thisexhibit was to expose in a concise way — without furtherconsideration of the mathematical aspects — themethodological bases of statistical modeling using a new classof statistical models called Generalized Additive Models forPosition, Scale and Shape (GAMLSS) proposed by RIGBYand STASINOPOULOS (2005). The application of the GAMLSSmethod to design a model with empirical data wasdemonstrated, as well as the use of diagnostic tools and theselection of the model of best fit, the construction of a curve ofreference and easier calculation of percentiles and z-scoresthrough specific functions. It is concluded that the GAMLSSmethod is an important tool for statistical modeling inhealthcare and that in future research it will probably be thestate of the art in the construction of new reference curves or inthe validation of curves already built.


Subject(s)
Epidemiologic Methods , Models, Statistical , Regression Analysis
7.
Rev. bras. ciênc. saúde ; 10(2): 189-196, maio-ago. 2006. ilus
Article in Portuguese | LILACS | ID: lil-469168

ABSTRACT

Hemorragia intraventricular (HIV) é uma importante causa de mortalidade e morbidade em recém-nascidos de muito baixo peso. Consequências desastrosas podem ocorrer principalmente se o diagnóstico for tardio. Vários fatores de risco associados a HIV tais como, baixo peso ao nascimento e prematuridade, foram identificados. Por outro lado a sobrevivência de recém-nascidos de muito baixo peso tem crescido significativamente nas últimas décadas.


Intraventricular hemorrhage (ICV) is an outstanding cause of mortality and morbidity of very low weight newborns. Disastrous consequences may mostly occur if the diagnosis is made in a late stage. Several risk factors associated with ICV, such as low weight at birth and prematurity, have been identified. On the other hand, the survival of extremely low-weight newborns has increased significantly in the last decades.


Subject(s)
Humans , Male , Female , Infant, Newborn , Intracranial Hemorrhages , Infant, Newborn , Infant, Premature , Risk Factors
8.
Rev. bras. ginecol. obstet ; 28(1): 3-9, jan. 2006. tab, graf
Article in Portuguese | LILACS | ID: lil-430955

ABSTRACT

OBJETIVO: construir curva de altura uterina em função da idade gestacional em gestantes de baixo risco e comparar os valores com os da curva adotada nacionalmente. MÉTODOS: estudo observacional e prospectivo. A amostra foi constituída por 227 gestantes atendidas no setor de pré-natal de dois serviços públicos de saúde de João Pessoa, PB. Foram incluídas mulheres com idade gestacional de certeza, feto único, vivo e sem malformações, sem condição patológica materno-fetal conhecida que pudesse afetar o crescimento fetal, com peso corporal normal e não-fumantes. As gestantes foram submetidas à medição padronizada da altura uterina entre a 13ª e a 39ª semana. A idade gestacional (foi confirmada por ultra-sonografia. O mesmo observador realizou 1206 medidas de altura uterina, com média de 5,3 medidas por gestante. Para análise estatística, adotou-se nível de significância de 5 por cento. Foram construídas tabelas e curvas com os valores dos percentis 10, 50 e 90 da altura uterina em função da idade gestacional. RESULTADOS: os valores dos percentis 10, 50 e 90 da altura uterina em cada idade gestacional permitiram a construção de curva padrão de altura uterina por idade gestacional em gestações de baixo risco. A análise comparativa visual entre as curvas mostrou que elas são diferentes. A diferença entre os valores médios de altura uterina deste estudo e os valores da curva adotada pelo Ministério de Saúde foi significativa a partir da 19ª semana de gestação. CONCLUSÃO: as duas curvas de altura uterina podem ter desempenhos diferentes quando utilizadas na assistência pré-natal para rastrear desvios do crescimento fetal. A curva padrão de altura uterina por idade gestacional construída deverá ser validada posteriormente para uso como padrão de normalidade.


Subject(s)
Pregnancy , Humans , Female , Gestational Age , Prenatal Care , Risk Factors
9.
Rev. ciênc. méd., (Campinas) ; 13(4): 371-380, out.-dez. 2004. ilus
Article in Portuguese | LILACS | ID: lil-400857

ABSTRACT

O objetivo desta revisão ê assinalar a importância da medição da altura uterina na assistência pré-natal. Contextualiza a assistência pré-natal em relação à redução da morbimortalidade perinatal e em relação à prevenção de restrição ao crescimento fetal. Resgata históricamente a utilização da medição da altura uterina, num período que vai desde o século XVIII até o século XX. Demonstra, para os setores de atenção básica à gestante, o valor da medida da altura uterina e a utilização da curva da altura uterina por idade gestacional, para identificar-se fetos em risco de apresentar baixo peso ao nascer. Descreve as conclusões de vários estudos, em diferentes países, valorizando a utilização de curvas de altura uterina, e alertando para a necessidade de padronização da técnica de medição da altura uterina, bem como da utilização de padrões de referência adequados à cada população, para obtenção de melhores resultados. Discute também os aspectos técnicos e metodológicos da curva padronizada pelo Ministério da Saúde, alertando para as possíveis limitações da utilização de curvas da altura uterina construídas com dados de populações etnicamente distintas. Em conclusão, ressalta a recomendação dos estudos citados, para que se construam as curvas da altura uterina por idade gestacional, a partir de dados próprios de grupos populacionais mais homogêneos em relação à população-alvo.


Subject(s)
Humans , Female , Pregnancy , Gestational Age , Prenatal Care
11.
Article in Portuguese | LILACS | ID: lil-476430

ABSTRACT

O objetivo deste estudo foi o de determinar a aplicabilidade e a precisão de equações de Bioimpedância (BIA) previamente publicadas na avaliação da composição corporal de 29 meninos brasileiros (10 a 14 anos). O DXA (DPX-IQ, Versão 4,6 A) foi usado na obtenção da gordura relativa (%G) e da massa corporal magra (MCM) de referência. A resistência corporal total foi medida com o analisador Biodynamics â (Modelo - 310). Foram analisadas as equações de Houtkooper et al. (1992), Jenkins et al. (1999), e as equações B2, B3 e B4 de Yonamine & Pires Neto (2000). Os resultados encontrados foram: o coeficiente de validade (r) do Biodynamics variou de 0,87 (B3/Yonamine) a 0,98 (Houtkooper); o erro de estimativa padrão (EPE) e o erro total (E) variaram de 1,88kg (Jenkins) a 3,66kg (B3/Yonamine). A equação de Houtkooper e a de Jenkins forneceram estimativas aceitáveis tanto da média da MLG quanto do EPE (1,97 e 1,88kg, respectivamente). As equações B2, B3 e B4 superestimaram de forma significativa a MCM (EC = -27,33kg; EC = -10,77kg; e EC = -1,97kg, respectivamente). Baseados nesses resultados é recomendável o uso da equação de Jenkins et al. (1999) ou a de Houtkooper et al. (1992) na estimativa da composição corporal de meninos brasileiros jovens e sadios da presente amostra.


The purpose of this study was to determine the applicability and predictive accuracy of previouslypublished total-body resistance Bioimpedance (BIA) equations for estimation of body composition of 29Brazilian boys (10 to 14 years old). A DXA (DPX-IQ, Version 4.6 A) was used to obtain reference measuresof relative body fat (%BF) and fat free-mass (FFM). Total-body resistance was measured with a Biodynamics Ò (Model-310) analyzer. The BI equations of Houtkooper et al. (1992), Jenkins et al. (1999), and Yonamine & Pires Neto (2000) B2, B3 and B4 equations were cross-validated. The results were asfollows: the validity coeficients (r) from the Biodynamics ranged from 0.87 (B3 Yonamine equation) to 0,98 (Houtkooper equation); the prediction errors (SEE and E) ranged from 1.88 kg (Jenkins) to 3.66 kg (B3 Yonamine). The Houtkooper and Jenkins equations accurately estimated average FFM with an acceptable prediction error (SEE = 1.97 and 1.88 kg, respectively). The B2, B3 and B4 Yonamine equationssignificantly overestimated average FFM by 27.33 kg ; 10.77 kg and 1.97 kg, respectively. Based on these results, we recommend using the Jenkins et al. (1999) equation, or the Houtkooper et al. (1992) equation to estimate body composition of young, healthy, Brazilian boys.


Subject(s)
Humans , Male , Child , Adolescent , Body Composition , Electric Impedance , Obesity
12.
Rev. bras. ciênc. mov ; 8(4): 14-20, set. 2000. tab, graf
Article in Portuguese | LILACS | ID: lil-284095

ABSTRACT

[1]Marques, M. B., Heyward, V., Paiva, C. E., Validaçäo cruzada de equaçöes e bio-impedância em mulhers brasileiras por meio de absortometria radiológica e dupla energia (DXA). Rev. Bras. Ciên. Mov. 8(4): 14-20, 2000. O objetivo deste estudo foi o de determinar a aplicabilidade e a precisäo da avaliaçäo da composiçäo corporal de 44 mulheres brasileiras (de 20 a 40 anos) do analisador de Bio-impedância (BI) dos membros superiores (OMROM tm)e das equaçöes, previamente publicadas, do tradicional BI. O DXA (DPX-IQ, Versäo 4,6 A)foi usado na obtençäo da gordura relativa ( por cento G) e da massa corporal magra (MCM) de referência. A resistência dos membros superiores foi medida com o OMROM tm (HBF 300), e a resistência corporal total foi medida com o Biodynamics â (Modelo - 310). Foram analisadas as equaçöes: de Lohman (1992), de Gray et al. (1989), de Segal et al. (1988), modificada por Stolarczyk et al.(1997) e a do OMRON tm (1998). Os resultados encontrados foram: o coeficiente de validade (r) do Biodynamics variou de 0,84 (Lohman) a 0,92 (Stolarczyk): o erro de estimativa-padräo (EPE) e o erro total (E) variaram de 1,61Kg (Stolarczyk) a 2,51 Kg (Gray). O r, o EPE e o E do BI dos membros superiores (OMROM tm) foram 0,87, 2,96 por cento G, e 4,92 por cento G, respectivamente. A equaçäo de Stolarczyk e a de Lohman forneceram estimativas aceitáveis tanto da média da MCM, quando do EPE (1,93 e 2,63Kg respectivamente). A equaçäo de Gray superestimou, de forma significativa, a MCM (D= 1,1Kg), e a equaçäo do OMROM tm subestimou o por cento G (D=4,92 por cento). Baseado nesses resultados, é recomendável o uso da equaçäo de Stolarczyk et al.(1997) ou a de Lohman (1992) na estimativa da composiçäo corporal de mulheres brasileiras jovens e sadias.


Subject(s)
Humans , Male , Female , Adult , Body Composition , Electric Impedance/therapeutic use
13.
Rev. bras. ciênc. saúde ; 3(1/3): 71-82, 1999. ilus
Article in Portuguese | LILACS | ID: lil-268904

ABSTRACT

O objetivo desta revisão é descrever as alterações hemodinâmicas da circulação uterina através do doppler colorido vaginal e da dopplervelocimetria das artérias uterinas, arqueadas e radiais durante o seguimento pós-molar, para determinar a sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do método no diagnóstico das formas localmente invasoras dos tumores trofoblásticos gestacionais. Os resultados de vários estudos dão suporte à recomendação da inclusão do DCV nos protocolos de seguimento pós-molar, uma vez que o método é capaz de discriminar precocemente, nas primeiras 4 quinzenas do seguimento pós-molar, tanto os casos que evoluem para remissão definitiva, quanto os que evoluem para tumor trofoblástico gestacional


Subject(s)
Humans , Female , Diagnostic Imaging , Trophoblastic Neoplasms/diagnosis , Ultrasonography, Doppler, Color
14.
São Paulo; s.n; 1998. 107 p.
Thesis in Portuguese | LILACS | ID: lil-272200

ABSTRACT

Foi realizado um estudo retrospectivo em 22 casos de astrocitomas cerebrais grau 11 (Daumas-Duport) para determinação dos índices percentuais de imunoexpressão de PCNA e Ki-67 utilizando-se a técnica da estreptavidina-biotinaperoxidase com os anticorpos monoclonais PC I O e N"- I. Entre os 22 pacientes 5 morreram (23 por cento ) e 17 estão vivos (77 por cento ). Dos que estão vivos, 9 estão sem tumor (53 por cento ) e 8 apresentam tumor (47 por cento ). A idade dos pacientes variou entre 12 e 53 anos. O tempo de acompanhamento clínico variou entre 5 meses e 7 anos. A média dos índices foi de 2,97 por cento para PCNA e de I,23 por cento para Ki-67. Não houve relação estatística significante entre os índices de proliferação celular nem com a idade nem com a condição clínica atual dos pacientes


Subject(s)
Follow-Up Studies , Trophoblastic Neoplasms , Ultrasonography, Doppler, Color
15.
J. bras. ginecol ; 104(10): 391-4, out. 1994. ilus
Article in Portuguese | LILACS | ID: lil-166889

ABSTRACT

Os autores definem e classificam a Gemelidade Imperfeita, informando a seguir os casos de gêmeos conjuntos, ou unidos, catalogados no Serviço. Informam que o diagnóstico de onfalópagus foi feito durante a assistência pré-natal através de ultra-som. No acompanhamento pré-natal a paciente fez um quadro de Doença Hipertensiva Específica da Gravidez na forma leve, sendo submetida a cesariana quando cursava a 38ª semana devido a Ruptura Prematura das Membranas. Nåo houve dificuldade na realizaçåo da intervençåo cirúrgica, tendo os gêmeos sido retirados pelos membros inferiores. Eram do sexo feminino e pesaram juntos 7.000 gramas. Após a realizaçåo de Rx simples do abdome dos recém-nascidos com estudo radiológico e ultra-sonográfico do trânsito do abdome, ficou evidenciado que as gêmeas tinham o duodeno, com cerca de 25 cm de intestino delgado em comum, e o fígado comunicando-se amplamente. A separaçåo cirúrgica foi realizada no 5§ dia de vida face a iminência de rotura da onfalocele, tendo o ato cirúrgico sido exitoso


Subject(s)
Humans , Infant, Newborn , Twins, Conjoined/surgery
16.
J. bras. ginecol ; 103(3): 85-7, mar. 1993. ilus
Article in Portuguese | LILACS | ID: lil-154130

ABSTRACT

Os autores tecem consideraçöes sobre casos publicados na literatura estrangeira e nacional de achados de gravidez abdominal, para, em seguida, relatarem um estranho encontro de rotura de gravidez abdominal avançada com feto vivo, com hemorragia severa dificultando a identificaçåo das aderências placentárias de grandes proporçöes. Descrevem, ainda, a execuçåo da laparotomia, ressaltando a hemorragia profusa que levou o paciente ao choque hipovolêmico, e informam que, face ás dificuldades para o estancamento da hemorragia crescente, utilizam, como recurso extermo, chuleio nas superfícies sangrantes, prendendo osvasos placentários e suturam quatro compressas, unidas entre si, ás superfícies cruentas. Por fim, comunicam que, decorridos 90 dias do ato cirúrgico, a paciente encontra-se em período de absorçåo da placenta, sob controles clínico e ultra-sonográfico, sem hipertemia


Subject(s)
Female , Pregnancy , Adult , Laparotomy , Pregnancy, Abdominal/complications , Uterine Hemorrhage/etiology , Pregnancy, Ectopic/surgery , Pregnancy, Abdominal , Rupture
SELECTION OF CITATIONS
SEARCH DETAIL